•     The NAVIPILOT 4000 Marine Autopilot uses advanced ship steering control network technology to steer a ship safely and efficiently.
        The innovative NAVIPILOT 4000 is capable of tuning itself to adapt automatically to the ship’s load characteristics and weather conditions.
  • autopilot
    autopilot
    autopilot
    autopilot
    auto pilot catalogue >
    ENVIRONMENT
    Ambient temperature range (operation) -15° C to +55° C
    Ambient temperature range (storage) -25° C to +70° C
    Protection grade (installed) IP32 to DIN 40050
    Standard magnetic compass 0.40m
    Environmental testing in accordance with EN 60945 (IEC 945 +A1)
    DIMENSIONS
    Front panel Dimensions 288 x 144 mm to DIN Standard
    Installation Depth 150 MM
    Weight 1.5 kg
    Front Panel Sealed Foil Keyboard, illuminated
    Display Graphic Liquid Crystal, illuminated
    STEERING CONTROL UNIT
    Protection grade IP32 to DIN 40050
    Magnetic clearance I0.4 m
    Dimensions 151 mm Height, 392 mm Width, 425 mm Depth
    Weight 3 kg
    Power requirements 24 VDC (18 V to 36 V)
    Maximum ripple content 4 V pp, extreme values should not exceed 36 V or fall below 18 V
    Power consumption 10 W max
    Reverse polarity protection Built-in
    Cable connection Clamp-type terminals
    POWER REQUIREMENTS
    Max ripple content 4 V pp, extreme values should not exceed 36 V or fall below 18 V
    Power consumption 10 W max
    Reverse polarity protection Built-in
    INPUTS
    Rudder angle feedback signal ±10 V ±120° max rudder angle potentionmeter resistance 2kW
    Power consumption 10 W max
    Flux gate for magnetic compass sine/cosine, C. Plath product
    NAV/TRACK interface NMEA 0183 (sentence selectable) from GPS, INS and others
    Speed input 200 p/nm or NMEA 0183
    180° turn command Port and starboard
    Gyro/magnetic selection
    Override status
    Mute
    Gyrocompass or electronic flux gate Two NMEA 0183
    Central alarm NMEA 0183
    Status signals AUTO, NFU, Helm, Remote, Ext System
    OUTPUTS
    DC Solenoid Valves
    Outputs Two for port, two for starboard (solid-state relays)
    Type Plus or minus switching
    Voltage 12 VDC to 110 VDC
    Rating 2.0 A max.
    Additional outputs Optional
    Inputs "Pump on” sense contact closure inputs
    AC Solenoid valves
    Outputs Two for port, two for starboard (solid-state relays)
    Voltage 24 VAC to 230 VAC
    Rating 1.0 A max.
    Additional outputs Optional
    Inputs "Pump on” sense contact closure inputs
    POWER REQUIREMENTS
    Max Ripple Content 4 V pp, extreme values should not exceed 36 V or fall below 18 V
    Power Consumption 10 W max
    Reverse Polarity Protection Built-in
    PROPORTIONAL RUDDER ORDER/ ERROR
    Outputs 80 mV/° to 350 mV/° (isolated) or 4 mA to 20 mA (isolated)
    Additional outputs Optional
    OUTPUTS AND INTERFACES
    Heading NMEA 0183
    Heading gyro HEHDT at 10 Hz
    Navigation system data NSD at 1 Hz
    Heading magnetic HCHDT or HCHDM or HCHDG at 10 Hz
    STATUS AND ALARM
    System alarm
    Off course alarm*
    Override alarm*
    Gyro/mag status*
    Ext system status*
    Deadman's control*
    Mute*
    * max 4 outputs selectable
    POWER FAILURE ALARM
    Primary supply Potential-free contacts
    Backup supply 2 A maximum current, 250 V maximum voltage